{"id":73,"date":"2022-07-08T16:19:54","date_gmt":"2022-07-08T19:19:54","guid":{"rendered":"https:\/\/exactas.uba.ar\/evento\/prueba\/?p=73"},"modified":"2023-07-11T10:28:45","modified_gmt":"2023-07-11T13:28:45","slug":"espectrometro-bruker-microtof-q-ii","status":"publish","type":"post","link":"https:\/\/exactas.uba.ar\/sic\/espectrometro-bruker-microtof-q-ii\/","title":{"rendered":"Espectr\u00f3metro de masas BRUKER micrOTOF-Q II"},"content":{"rendered":"<p>Analizador cuadrupolo &#8211; tiempo de vuelo que provee masas exactas con error menor a 3 ppm en EM y menor a 5 ppm en EM\/EM<\/p>\n<p>Fuentes de ionizaci\u00f3n a presi\u00f3n atmosf\u00e9rica: Electrospray (ESI), de Ionizaci\u00f3n qu\u00edmica (APCI) y de Fotoionizaci\u00f3n (APPI) con entrada de muestra directa o desde un cromat\u00f3grafo l\u00edquido. Fuente de desorci\u00f3n Electrospray (DESI)<\/p>\n<p>Fuente de ionizaci\u00f3n qu\u00edmica a presi\u00f3n atmosf\u00e9rica (APCI) con interfase dual para acoplar a cromat\u00f3grafo l\u00edquido y a cromat\u00f3grafo gaseoso<\/p>\n<p>Rango de masas: m\/z 20 &#8211; 40.000<\/p>\n<p>Rango din\u00e1mico 100.000:1<\/p>\n<p>Disociaci\u00f3n inducida por colisiones en la fuente (ISCID) y en la celda de colisi\u00f3n (CID) permite experimentos EM\/EM y EM\/EM\/EM<\/p>\n<p>Software de an\u00e1lisis de metabolitos y de an\u00e1lisis estad\u00edstico. Estaci\u00f3n de trabajo auxiliar<\/p>\n<p>Cromat\u00f3grafo l\u00edquido de ultraeficiencia RRLC Agilent 1200 con detector de arreglo de diodos<\/p>\n","protected":false},"excerpt":{"rendered":"Analizador cuadrupolo &#8211; tiempo de vuelo que provee masas exactas con error menor a 3 ppm en EM y menor a 5 ppm en EM\/EM Fuentes de ionizaci\u00f3n a presi\u00f3n atmosf\u00e9rica: Electrospray (ESI), de Ionizaci\u00f3n qu\u00edmica (APCI) y de Fotoionizaci\u00f3n (APPI) con entrada de muestra directa o desde un cromat\u00f3grafo l\u00edquido. Fuente de desorci\u00f3n Electrospray&#8230; <a class=\"view-article\" href=\"https:\/\/exactas.uba.ar\/sic\/espectrometro-bruker-microtof-q-ii\/\">LEER +<\/a>","protected":false},"author":1,"featured_media":659,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8,39],"tags":[],"class_list":["post-73","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dqo-umymfor","category-espectrometria-de-masas"],"acf":[],"_links":{"self":[{"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/posts\/73","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/comments?post=73"}],"version-history":[{"count":4,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/posts\/73\/revisions"}],"predecessor-version":[{"id":1464,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/posts\/73\/revisions\/1464"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/media\/659"}],"wp:attachment":[{"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/media?parent=73"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/categories?post=73"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exactas.uba.ar\/sic\/wp-json\/wp\/v2\/tags?post=73"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}